Cromatest Glucose MR Reagent for Bio Chemistry Analyzer for Reliable RBS
Packaging Size: (4x 100) ml
Origin: Spain
Brand : Cromatest / Linear
Packaging Type: Bottle
Test/Pack: 100 Test
Method: CNPG3. Kinetic

Standard Delivery
Delivery in 2-3 days
1 Year Warranty
Manufacturer warranty
Easy Returns
7 days return policy
Packaging Size: (4x 100) ml
Origin: Spain
Brand : Cromatest / Linear
Packaging Type: Bottle
Test/Pack: 100 Test
Method: CNPG3. Kinetic
Applications: Diagnostic
Format: Liquid
Tested Parameter: For Transferrin
Storage temperature :Min.: 2 °C (36 °F) – Max.: 8 °C (46 °F)

In the Trinder reaction1,2, the glucose is oxidized to D-gluconate by the glucose oxidase (GOD) with the formation of hydrogen peroxide. In the presence of peroxidase (POD), a mixture of phenol and 4-aminoantipyrine (4-AA) is oxidized by hydrogen peroxide, to form a red quinoneimine dye proportional to the concentration of glucose in the sample.

R1- Monoreagent. Phosphate buffer 100 mmol/L pH 7.5, glucose oxidase > 10 KU/L, peroxidase > 2 KU/L, 4- aminoantipyrine 0.5 mmol/L, phenol 5 mmol/L.
CAL: Glucose standard. Glucose 100 mg/dL (5.55 mmol/L). Organic matrix based primary standard. Traceable to SRM 914a and 909.STORAGE AND STABILITY
Store at 2-8ºC.
The Monoreagent and Standard are stable until the expiry date stated on the label. Discard the reagent if presents an absorbance over 0.300 at 500 nm against distilled water or if it fails to recover the declared values of control sera. .
The Monoreagent and the Standard are ready-to-use.
Serum or heparin plasma free of hemolysis. Glucose is stable up to 24 hours at 2-8ºC when serum or plasma is separated within 30 minutes after collection
|
The color is stable for about 2 hours protected from light.
Samples with concentrations higher than 500 mg/dL should be diluted 1:4 with saline and assayed again. Multiply the results by 4. If results are to be expressed as SI units apply: mg/dL x 0.0555 = mmol/L
Serum, plasma (fasting)
|
It is recommended that each laboratory establishes its own reference range.
The use of a standard to calculate results allows to obtain an accuracy independent of the system or instrument used.
To ensure adequate quality control (QC), each run should include a set of controls (normal and abnormal) with assayed values handled as unknowns.
Glucose is a major energy source for the human body, derived from the breakdown of carbohydrates obtained from daily diet and regulated through the process of glycogenolysis (breakdown of body stored glycogen), and gluconeogenesis (endogenous synthesis from aminoacids and other substances).
The glucose level in the blood is maintained by diet uptake and regulatory hormones such as insulin, glucagon, or epinephrine.
An abnormal increase in blood glucose level, referred as hyperglycemia, can be associated with diabetes mellitus and hyperactivity of thyroid, pituitary or adrenal glands.
An abnormal decrease beyond the fasting level, referred as hypoglycemia, is observed in cases of insulin overdose, insulin secreting tumors, mixedema, hypopituitarism, Addison´s disease and conditions interfering with glucose absorbtion.
Glucose measurement in the blood is a key test to evaluate and diagnose any carbohydrate-related disorder.