Colenta CR (Computed Radiography) System

৳ 1,350,000৳ 1,400,000 (-4%)

In stock

  • Colenta CR is a table-top reader unit that boasts a world-class high processing speed of 73 IPs/hour.
  • In the high-speed mode (5 pixels/mm), throughput is enhanced by almost 70% compared with other CR (only for IPs of 14″ × 17″ and 14″ × 14″ ).
  • As with all Colenta equipment, Colenta CR is easy to operate.
  • It will help reduce patient waiting time and greatly increase the efficiency of the examination workflow.
  • Colenta CR, with its light and compact tabletop design, can be placed on a desk, shelf or anywhere space is limited.
  • As this is a fully digital reader, neither a darkroom nor automatic processor is required.
  • Colenta CR can always be installed in the space formally used by a chemistry-based processor.
  • Brand COLENTA
  • Origin AUSTRIA

Frequently Bought Together

Colenta CR (Computed Radiography) System

DX Easy Imaging CR Retrofit Kit HighCap Xr

Processing Capacity

Up to 47 IPs/hr in size 14“x17“ (35cmx43cm). The Colenta DX Easy Imaging CR Retrofit Kit HighCap Xr is a table-top reader unit that boasts a world-class high processing speed of 73 IPs/hour*. As with all Colenta equipment, the DX Easy Imaging CR Retrofit Kit HighCap Xr is easy to operate. It will help to reduce patient waiting time and greatly increase the efficiency of the examination workflow.

*) The above value is for IPs of 8” x 10” (18cmx24cm)

Reading Resolution – Pixel Size

One of the reader’s key components is the Imaging Plate, or IP, which is used instead of the X-ray film to easily digitize X-ray images.

Space-Saving Design

All of  Colenta’s equipment the Colenta DX Easy Imaging CR Retrofit Kit HighCap Xr is easy to operate. It will help to reduce patient waiting time and greatly increase the efficiency of the examination workflow.

The minimum requirement of PC is core i5 processor with 3.2 GHz clock speed & 4GB RAM. 2 x 500 GB SATA Harddisk & RAID supported motherboard are required. 2 x GBit LAN Controller and VGA graphic controller with 24bit color depth.

Colenta CR

 

Specifications

Image Plate General X-ray 14” x 17” (35cm x 43 cm), 14” x 14” (35cm x 35 cm),10” x 12” (24cm x 30cm), 8” x 10” (18cm x 24cm), 15cm x 30cm
Processing Capacity 14” x 17” (35cm x 43 cm) up to 47 IPs/hr8” x 10” (18cm x 24cm) up to 73 IPs/hr
Time Required for IP Feed/Load Min. 49 sec
Time to Start on Display Min. 33 sec.
Grayscale resolution 12 Bit
Reading Specification 5 pixel/mm, 10 pixel/mm, 20 pixel/mm (Mod. XMr)
Pixel Size 100um, 50 um (mod. XMr)
Number of Stacker 1
Network 10 Base T/100 Base-TX
Weight 39 kg (86 lbs.)
Dimensions (WxDxH) 560mm x 540mm x 392 mm (22” x 21” x 15”)
Power Supply Conditions Single-phase 50-60Hz, AC120-240V±10%
Environmental Conditions Temperature: 15-30°CHumidity: 40-80%RH (No dew condensation)

This equipment is a Class 1 laser product (IEC60825-1:2001).

Specifications are subject to change without notice. All brand names or trademarks are the property of their
respective owners. In some countries, regulatory approval may be required to import medical devices.

reader highcap xr

Buy 500mA X-Ray Machine lowest price in Bangladesh 

COLENTA Dicom Printer HighCap XLp

COLENTA Dry Laser Imager – High Efficiency – Mammo Applicability

  • Processing Capacity: up to 110 films/hr, size 35×43 cm (14″ x 17″) helps to reduce patient’s waiting time, increasing efficiency of examination workflow.
  • Printing Resolution – Pixel Size: up to 508 dpi (50µm), allows printout of Mammo Images
  • Two Film Tray Online : 3 universal film trays enabling printing of 3 different sizes at the same time
  • Colenta DICOM Printer HighCap XLp to be used with Colenta Dry Laser Films to obtain a maximum quality printout of examination images.

 

60adf790d12c1

HighCap XLp Specifications :

  • Recording method
    Laser exposure thermal development system
  • Applicable film
    MEDIPHOT DRY IMAGING FILM DL (100/150 sheets/pack)
    35cm x 43cm (14” x 17”), 26cm x 36cm (10” x 14”),
    25cm x 30cm (10” x 12”), 20cm x 25cm (8” x 10”)
    MEDIPHOT DRY IMAGING FILM DLM for Mammography            (150 sheets/pack)
    26cm x 36cm (10” x 14”), 25cm x 30cm (10” x 12”), 20cm x 25cm (8” x 10”)
  • Film loading
    Daylight film loading
  • Film magazines
    Up to 3 trays online
  • Processing Capacity
    approx. 110 sheets/hour 35cm x 43cm (14” x 17”)
    approx. 160 sheets/hour 20cm x 25cm (8” x 10”)
  • Pixel size
    50 um (508 dpi) / 100 um (254 dpi)
  • Recording gradation
    14 bits (16383)
  • Image memory
    1GB
  • Density Adjustment
    Automatic density correction
  • Input channels
    DICOM network input (max. 10 simultaneous connection associations)
  • Dimensions (WxDxH)
    610mm x 630mm x 1125mm (24” x 25” x 44”) – without sorter
  • 610mm x 630mm x 1425mm (24” x 25” x 56”) – with sorter
  • Weight
    125 kg (275.6 lbs.)
  • Power Supply Conditions
  • Single phase 50-60Hz, AC100-240V ±10%
  • Operating Conditions
  • Temperature: 15 to 30°C (59 to 91°F)
    Humidity: 15 to 70% rH, non-condensing
    Atmospheric pressure: 750 to 1060 hPa

printer highcap xlp

 

Brand

Colenta

Be the first to review “Colenta CR (Computed Radiography) System”

Reviews

There are no reviews yet.

Main Menu

Colenta CR (Computed Radiography) System

৳ 1,350,000৳ 1,400,000 (-4%)

Add to cart