  • 12 inch high-resolution color screen
  • Exquisite design suitable to moving operation
  • Operation interface: Standard, Trend Screen, oxyCRG Screen, NIBP List, Big front Screen
  • Freeze instant waveform for real time S-T segment analysis, pace-maker detection
  • Storage for up to 400 groups of NIBP list, 60 alarm events records recall
  • Built-in rechargeable lithium battery with 4hours working capacity
  • Capture dynamic wave forms
  • Patient info input management function

Portable Patient Monitor 12.1 Inch Color with 6 Standard Parameters:

Features:   

  • Ergonomic design, portable, convenient for use
  • 12.1″ TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti-AC & high-frequency electrosurgical & defibrillator interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead, and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis, and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Optional software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, Turkish.
  • Super long life rechargeable Lithium battery up to 4 hours of working time
  • Suitable for adult, pediatrics, and neonate patients

Standard configuration:

  • ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery

Optional:

  • Dual TEMP
  • Dual IBP
  • ETCO2 (side stream)
  • Thermal recorder
  • Wall mount
  • Trolley

Portable Patient Monitor

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heartbeat LORENZO drawing: Analysis on heartbeat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope:     ±0.8mV
Precision:  < ±0.05mV

SpO2

Detection scope:   0%-100%
Accuracy                 ±1%     90%-100%
±2%      70%-89%

NIBP 

Theory Electric oscillator
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate:  ±2%

Portable Patient Monitor

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method     0 time/minute – 100 minutes/minute
The precision of chest impedance method  time/minute
Detection scope of carbon-oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute

Temp

Single/double path
Type:    Vascular/surface temperature
Scope:    20℃~50℃
Accuracy:  ±0.2℃

Invasive blood pressure (optional)

Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV

Brand

Yunker

Average Rating

5.00

01
( 1 Review )
5 Star
100%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Add a review

1 Review For This Product

  1. 01

    by Souvik Ahmed

    Assalamuya Laikum! i was hesitate to order this monitor here but my close someone said this site was trusted so i ordered here and got too early! Satisfied in delivery system… Does everything it says it will do so far. I’m very pleased with this. Great value and it performs quite well.
    It has all the features I wanted!! Great features and performance, excellent display. The built-in help is really good.
    THanks Medistore, will buy again any systems that we need for our clinic in future!

Main Menu

Portable Patient Monitor

Portable Patient Monitor 12.1 Inch Color with 6 Standard Parameter

৳ 55,000৳ 65,000 (-15%)

Add to cart